Transcribe the designation before naming the cable
Photograph and copy the complete readable jacket legend, including a TC, TC-ER, PLTC, or other printed designation if present. Pair the jacket photo with the reel tag, manufacturer, and part number. A location in a tray, control room, or project is background information; it does not establish the product designation.
If part of the legend is obscured, record the readable portion and mark the rest unknown. Do not promote a likely classification into a confirmed label. The useful next record is a better photo or a matching data sheet tied to that reel ID.
- Designation
- manufacturer
- part number
- photo reference
Split assemblies that merely look alike
Create separate lines when conductor count, pair count, gauge, shield, or jacket differs. A reel marked 12 conductors and a reel marked 16 conductors should not become a single control-cable total, even if their jacket color and storage shelf match. Keep the exact field values visible on the individual line.
Describe shielding as shown by a product record or mark it unknown. Do not infer foil, braid, or another construction feature from a partial photograph. This separation protects the seller from presenting a generic multi-conductor total that cannot be traced to the individual reels.
- Conductor count
- pair count
- gauge
- shield
- jacket
Keep length and history with the reel
For each reel, report continuous footage and its basis as measured, documented, estimated, or unknown. Add status such as project overrun, uninstalled stock, or cable taken out of service, and show fitted ends where they are present. Two short pieces do not become one long continuous length when their footage is added.
Use the reel reference in photo filenames and any data-sheet filename. If a service history is incomplete, say unknown and retain the visible condition record. The page concerns clear inventory evidence, not a declaration about electrical suitability.
- Reel ID
- continuous footage
- quantity basis
- status
- fitted ends
Attach evidence and state the gaps
Match readable jacket photos, labels, and existing data sheets to the same inventory line. Include visible damage and the precise unknown fields. A data sheet for a different part number should not be used as if it identifies the offered reel, and an unreadable legend should stay unreadable in the record.
A focused photo request is more valuable than an invented answer. The seller can note that the shield status is unknown, attach the corresponding jacket image, and leave the buyer with a specific field to review rather than an unreliable all-purpose cable description.
- Data-sheet reference
- unknown fields
- visible damage
- matching photo filenames
Keep the Redmond reference proportionate and fix tray-only classification
The City says its business resources include maps, parking, commuting resources and environmental considerations, plus building resources for property and commercial-land development. The City statement supports a practical storage and access context for a seller’s own project record; it does not show that any named business has control cable available or that a local transaction occurred.
The error is calling every cable from a tray Type TC and combining conductor counts. Correct it by using actual markings, separate assembly lines, and reel-level history. Illustrative fictional inventory record—not a purchased lot: CT-01; TC-ER marking; 12 conductors, 16 AWG; shielding unknown; 240 ft measured; cable taken out of service; fitted ends present.
- Use location as background only.
- Retain unknown fields instead of guessing a designation.
