Confirm the conductor metal from the product record
Use the reel tag, complete jacket printing, or a matching manufacturer record to document conductor metal. Record the manufacturer, part number, full designation, insulation or jacket, and the source of the metal identification. A visual observation of a silvery conductor is worth noting, but it cannot by itself establish every conductor or member in an assembly as aluminum.
If paperwork and printing disagree, preserve both observations under the same reel reference. Mark the metal as unconfirmed until the conflict can be resolved. Do not replace missing detail with a category selected from color, diameter, or the location where the feeder was stored.
- Photograph the tag and the longest readable jacket legend.
- Record the source used to identify conductor metal.
- Mark conflicting or missing details as unconfirmed.
Describe the whole feeder assembly
An aluminum feeder can have a neutral, shield, support member, or other mixed construction element. Put conductor count, neutral detail, shield detail, support member, and mixed-metal notes in distinct fields. This avoids the inaccurate shortcut of converting one observed exposed conductor into a description of the whole cable.
Where a member is not identified by the tag or record, state unknown rather than estimating its material. Keep copper and aluminum quantities on separate lines when they are known to be distinct; where a mixed element cannot be separated, describe the assembly and the uncertainty without creating a combined metal total.
- Conductor count and neutral are separate fields.
- State shield and support-member details only when supported.
- Explain mixed construction rather than forcing one metal total.
Reconcile each reel balance
For each feeder reel, compare the current visible balance with the original tag. Record the reel ID, full or partial status, remaining continuous footage, and whether that footage is measured, documented, estimated, or unknown. A partial reel must not inherit the original shipped length merely because the original tag is still attached.
Photograph accessible ends, the flange, and visible jacket condition under the same reference. Report a known gross, net, or estimated weight with its basis; if the basis is not known, say so. These records describe the inventory without implying a condition assessment or a transaction term.
- One reel ID per line or matching group.
- Keep original footage and current balance in separate fields.
- Label full, partial, measured, documented, estimated, or unknown status.
Apply the Renton local fact within its limits
Renton Public Works says its Maintenance division operates and maintains streets, sidewalks, bridges, equipment, water, wastewater and surface-water utility systems.
This public-works statement supplies local infrastructure context only. It does not show that a public entity owns the cable or is offering a feeder. Its limited relevance here is to remind a Renton seller to identify the actual storage setting, access restriction, release authority, and loading information rather than assume a standard site arrangement.
- State storage site and access restrictions.
- Identify available loading resources as observed.
- Record the person or role that can authorize release, or mark it unknown.
Illustrative fictional feeder record
Illustrative only: AL-RN-02 is a partial feeder reel with an aluminum designation copied from the reel tag and neutral detail documented. Its 275 ft balance is estimated, the exposed end and jacket are photographed, and the weight basis is unknown. The record does not convert the visual appearance of the end into proof about every component.
A real record can add a matching data sheet or measured balance when available. Until then, the useful action is to keep the unconfirmed field visible and tie every photo and document to AL-RN-02.
- Reference: AL-RN-02
- Quantity: 275 ft continuous, estimated; partial reel.
- Condition: exposed end noted; jacket photographed.
- Weight: unknown basis.