Use the local fact as context, then document the actual lot
Washington ESD reports 2024 annual-average Yakima County covered employment of 29,212 agriculture, forestry, fishing and hunting jobs and 7,853 manufacturing jobs. Those numbers are only local context for a mixed commercial-inventory workflow; they are not evidence of a particular cable lot, customer, or demand.
The material decision here is not whether a pile appears copper-colored. It is whether every line has evidence for conductor metal, construction, condition, quantity, ownership, and release. That makes this page different from building-wire balance reconciliation, which begins with individual marked conductor reels.
- Metal evidence source
- Manufacturer and part number when available
- Uncertainty note for unsupported identity
Establish metal identity without guessing
Use a reel label, jacket printing, or a matching manufacturer record to identify copper or aluminum. Photograph the source and link it to the same inventory reference. A silvery surface, a painted jacket, or an assumed conductor weight is not a reliable substitute for a record; when evidence does not settle the metal, label the line unconfirmed.
Keep an unconfirmed line separate from identified cable. This preserves an honest record without converting an uncertainty into a claim. It also lets a later tag, part number, or data sheet update only the correct line.
- Label or jacket evidence
- Photo reference
- Manufacturer specification if matched
- Unconfirmed identity when evidence is incomplete
Separate construction and weight basis
List bare conductor, insulated wire, multi-conductor cable, armored cable, and mixed recovery-only pieces as different constructions. For each, record insulation, conductor count when known, condition, and any continuous length. An identifiable reel should not disappear inside a mixed-pieces total.
State whether a reported weight is gross loaded reel, gross bundle, cable-only, net, or estimated, and say whether wood, steel, or packaging is included. Gross weight is useful handling information, but it is not verified copper or aluminum conductor content.
- Construction and insulation
- Conductor count
- Weight value and weight basis
- Reel or packaging included
Keep authority and unknowns visible
Match photos to every line and state its location, ownership or seller authority, and release status. A continuous length with a readable label should stay separate from unknown fragments, even if both are stored together. This gives the buyer a clearer material record and gives the seller a concrete list of gaps to resolve.
If length, conductor weight, or release authority is not known, enter unknown and state the available evidence. Do not derive conductor weight from a loaded wooden reel, and do not imply that a material line can be released before the seller has confirmed authority.
- Continuous length
- Location
- Ownership or release authority
- Unknown-field explanation
Correct the loaded-reel claim
The mistake is advertising a 900 lb loaded wooden reel as 900 lb of copper while aluminum and recovery-only pieces are mixed into the same total. The corrective record states the gross loaded-reel weight accurately, leaves conductor content unknown unless documented, and separates copper, aluminum, uncertain, and recovery-only lines by construction.
Illustrative inventory example—not a purchased lot: MA-YAK-03; identified insulated copper conductor from reel label; 900 lb gross loaded reel; conductor weight unknown; continuous footage not yet documented. This fictional example labels both the useful evidence and the limitation.
- Do not convert gross reel weight to conductor weight
- Separate identified long lengths from mixed pieces