Begin with the reel-specific rating
Photograph and transcribe the marked kV, manufacturer, complete part number, conductor size, and conductor metal from the offered reel. Keep the reel ID in the image filename and the inventory line. A broad voltage label, project name, or visually similar product cannot replace the marking on the physical reel.
WVDOT reports that its Charleston Metro Projects program includes more than 50 planned and active bridge projects focused on rehabilitating and replacing aging bridges, with maps, schedules and traffic-management information. It supports only a labeled infrastructure-related surplus scenario; it does not show that medium-voltage cable exists at a project, is releasable, or is suitable for purchase.
- Reel ID and photo references
- Exact marked kV, manufacturer, and complete part number
- Conductor size and metal when shown by the item or matching record
- Continuous length with measured, documented, estimated, or unknown basis
Link construction records to the same reel
Record insulation level, shield or neutral construction, and jacket details only when the reel or a matching document supports them. Identify the data-sheet ID, batch or lot ID, record date, and scope. A record that lacks the offered reel or batch identifier may be retained as background, but it should not be presented as documentation for the offered item.
The important task is traceability, not a long stack of files. One matching record with a clear reel relationship is more useful than several similar documents with no item connection.
- Insulation level, shield or neutral, and jacket detail
- Matching data-sheet ID
- Batch or lot ID
- Record date and scope that match the offered reel
Describe visible condition without adding claims
Document continuous footage, end protection, accessible jacket condition, known moisture exposure, and storage history. Photographs should show the reel, readable markings, accessible ends, and any visible issue. Those facts help explain the record, but they are not a statement that the cable meets any electrical or reuse standard.
If a record describes another reel, keep that mismatch visible. The seller gains more from a clear limitation than from a borrowed rating or a condition conclusion that the evidence cannot support.
- Continuous footage and quantity basis
- End-protection status
- Known storage or moisture-exposure history
- Visible jacket condition and photo reference
Leave gaps intact when records are missing
A common inventory mistake is attaching a certificate or specification from a similar reel to the offered reel. That can conceal a different batch, kV marking, insulation system, or footage. The resolution is to retain only the matched record as supporting evidence and to mark missing fields directly in the inventory.
For a missing end cap, unreadable marking, or unavailable batch document, describe the observed issue, attach the relevant photo, and label the record gap. Do not manufacture a technical classification from nearby inventory or a project file.
- Unknown fields identified in the reel record
- Mismatched documents labeled with their own reel or batch ID
- Photo of missing end protection or unreadable marking
- No borrowed kV, insulation, or batch specification
Illustrative voltage-rated reel record
The following is an illustrative fictional record—not a purchased lot. It gives a specific marked rating, a documented length, and a record gap without suggesting that the gap has been resolved.
A real submission should use its own reel ID, photos, and supporting records. The example does not claim electrical condition, acceptance, or any commercial term.
- Line: MV-CHAR-02
- Product: 15 kV marking photographed; insulation level unknown
- Quantity: 720 ft documented
- Records: one missing end cap; no matching test record located