Identify cable by its construction, not its room
A facility name, equipment label, or electrical-room location is useful background but not a cable specification. Create a line for each reel or continuous piece using the manufacturer, part number, product designation, conductor count and size, marked voltage, and known shield or armor. Photograph enough of the jacket legend to preserve the readable text.
Do not fill a missing construction field from a nearby machine or a similar-looking reel. When a label or record cannot be tied to the offered piece, write unknown. That keeps the inventory useful without claiming that facility association proves a product rating.
- Transcribe the full readable jacket legend.
- Record manufacturer and part number before using a facility description.
- Mark shield or armor unknown when it is not supported by the piece or record.
Separate stock from removed runs at the first pass
Build separate lines for uninstalled maintenance stock, installed-and-removed cable, and material with mixed or incomplete history. Record fitted ends, visible jacket damage, storage exposure, and the known service-history category with the specific reel reference. A clean-looking reel should not cause a removed run to be listed as uninstalled stock.
This separation answers the real closeout question: what does each line represent today? It also prevents a buyer from having to reconstruct condition later from a mixture of inventory types. If history is unknown, say so and preserve the photos and available record scope instead of assigning a status by appearance.
- Use separate status lines for uninstalled and removed material.
- Photograph fitted ends and visible jacket damage where safely accessible.
- State storage exposure and unknown service history plainly.
Bind documents and photos to the offered piece
Give every reel or continuous piece a reference and use it in the inventory file, photo names, data-sheet note, and existing record list. If a drawing, purchase record, or inspection document exists, record its identifier, date, and what item it actually covers. A document for another reel is not evidence for the offered line.
For an incomplete record, the practical resolution is not to omit the item. Keep the line, record the continuous length with its quantity basis, and state which construction fields are unsupported. This lets the discussion focus on specific missing evidence rather than on an implied match.
- Match each document ID to one reel or continuous piece.
- State whether footage is measured, documented, or estimated.
- Keep an unknown field visible beside the evidence that remains.
Use Cheyenne facility context only as location context
The City of Cheyenne data-center page provides a map covering data centers and campuses operating, under construction and proposed in city limits or proposed city limits; it says the map does not include developments outside city limits. That map can help a seller describe a city-area facility context, but it does not show that a site has cable available, identify a product, or establish authority to sell.
For this task, the source matters only because it reinforces the need to describe a facility closeout accurately rather than infer inventory from a site label. The jacket legend, service-history line, and release record remain the evidence for the actual cable.
- Use a facility name as context rather than a cable designation.
- Do not infer inventory or ownership from a public map.
- Tie closeout records to the physical reel reference.
Prepare a closeout file a reviewer can trace
Include the owner or release authority, site location, available loading facts, and any access restriction with each completed line. These are seller-provided constraints, not a promise about handling. They let the material record stay connected to the person able to release it.
An illustrative record is IC-CY-01: manufacturer part number recorded; four conductors, 6 AWG; shield status unknown; 420 ft documented; uninstalled maintenance stock; facility approval required. It is fictional and not a purchased Cheyenne lot. Its value is the clear separation of construction, quantity, condition, and authority.
- Include owner or release authority for each offered line.
- Keep loading equipment and access restrictions factual or mark them unknown.
- Email the completed list and photos to saleselectricalbuyers@gmail.com.