Start with the printed product identity
Transcribe the manufacturer name, part number, product designation, and conductor-metal field from the reel tag, jacket printing, or a matching record. Keep the exact wording in the line item. Do not classify a reel from surface color, cable diameter, or the name of the project where it was stored.
When a tag is absent or unreadable, assign a stable line reference, photograph the available evidence, and mark product designation and metal as unknown. This preserves the distinction between a documented aluminum product and a visually assumed one.
- Manufacturer and part number transcribed exactly
- Conductor-metal field tied to a tag or matching record
- Missing or unreadable identity fields marked unknown
Describe the complete feeder assembly
An aluminum feeder can include conductor, neutral, shield, support, or messenger elements that should not be collapsed into one material statement. Record AWG or kcmil, conductor count, insulation or jacket designation, and any neutral, shield, or support description as separate fields. A mixed assembly remains mixed even if its main conductors are documented as aluminum.
If the supplied record names a component but does not identify its material, preserve that omission. The useful decision is whether the actual assembly is identified well enough for review, not whether every blank can be filled from a visual impression.
- AWG or kcmil and conductor count
- Neutral, shield, and support entries separated
- Jacket or insulation designation retained as documented
Reconcile partial-reel length and ends
List each full or partial reel separately. State remaining footage as measured, documented, estimated, or unknown, and keep that basis beside the reel ID. A partial reel should not inherit its original shipped length when the present balance is not known.
Describe visible end condition with neutral terms such as cut, protected, fitted, or unknown. The entry is an inventory record, not an electrical condition finding. Photos of the accessible ends and reel flanges give context for the stated facts.
- Reel ID and remaining length per reel
- Measured, documented, estimated, or unknown basis
- Visible end and reel condition noted
Record location and mixed-construction limits
Add storage exposure, current location, accessible loading notes, and known release authority to each line. A multi-reel feeder listing is easier to understand when the record shows which reels are at which site and which information has not been confirmed.
Gilbert provides five utility services; its water infrastructure includes wells, pumps, reservoirs and two drinking-water treatment plants. The fact is local utility context only; it does not show that any cable came from that infrastructure or that a particular aluminum lot exists. It supports keeping facility-oriented feeder records precise about assembly and location.
- Indoor, covered, or exposed storage
- Location and access facts
- Release authority or explicit unknown
Worked record and correction path
An illustrative row can read: AL-GIL-02; aluminum feeder designation from reel tag; 4/0 AWG documented; 275 ft estimated on a partial reel; neutral and support detail unknown. It says what the tag supports and avoids claiming that every component is aluminum.
If later paperwork conflicts with appearance, keep the documented record in the inventory and flag the inconsistent or missing component as unknown. Do not revise a line simply because an exposed surface appears silvery.
- Illustrative row names the evidence source
- Mixed or unconfirmed elements remain explicit
- Estimated footage is not presented as a measured balance