Transcribe the jacket designation first
Photograph and transcribe the complete readable jacket marking, including TC, TC-ER, PLTC, manufacturer, part number, and marked voltage where present. Cable previously stored or routed in a tray is not automatically Type TC. The printed designation and matching documentation are the useful identity evidence.
When only part of the legend can be read, enter the readable text and mark the remaining designation unknown. A close-up photo plus a stable reel ID is more useful than completing the abbreviation from where the cable was found.
- Printed designation and marked voltage
- Manufacturer and part number
- Reel ID linked to close-up photos
Keep near matches on separate rows
Use different rows for changes in conductor count, pair count, gauge, overall or individual shielding, or jacket construction. For example, a 12-conductor 16 AWG unshielded reel is not the same entry as a 12-conductor 16 AWG reel with an overall foil shield. The row distinction prevents a single footage total from masking construction differences.
Do not combine reels simply because the outer jacket is similar. If a shield or count cannot be confirmed, preserve it as unknown and do not merge it with a documented specification.
- Conductor count
- Pair count
- Gauge
- Shielding and jacket differences
Tie footage and ends to the actual reel
Record continuous length for each reel or piece and label its basis as measured, documented, estimated, or unknown. Photograph fitted ends or termination hardware and record them separately. A collection of cut pieces is not one continuous length, even when the printed designation happens to match.
Keep any data-sheet reference alongside the reel ID it supports. If the document cannot be connected to the item, record its limits rather than treating it as proof for the whole lot.
- Reel ID and continuous length
- Quantity basis
- Fitted ends
- Data-sheet reference with its scope
State history, location, and local context carefully
Identify whether each row is uninstalled stock, overrun, or removed cable. Add visible jacket damage, storage location, access facts, and release authority. These are inventory and handling facts, not a claim that the cable can be reused or that movement has been arranged.
Gilbert’s Transportation Master Plan is a 20-year vision for a multi-modal transportation network and was adopted August 23, 2022 after collaboration with business and regional partners. This source does not establish a cable lot or a transportation service. Its limited local relevance is why a multi-reel commercial record should keep its actual location and access facts as specific as its cable designation.
- Condition history
- Visible jacket damage
- Location and access notes
- Release authority or unknown
Worked record for a near-match decision
An illustrative row can read: CT-GIL-04; TC-ER marking photographed; 12 conductors, 16 AWG; shielding unknown; 240 ft measured; removed cable; fitted ends present. A second reel with a different shield field or pair count receives its own row even if it appears similar.
When a field remains unreadable, identify the uncertainty before the records are shared. The resolution is not to classify by tray location; it is to preserve the actual marking and keep uncertain construction separate.
- Illustrative row has reel-level quantity
- Near-match differences stay separate
- Unconfirmed construction remains unknown