What we need first
Begin by photographing the jacket legend and any reel labels. The single most important step is to transcribe the product designation exactly as printed (TC, TC-ER, PLTC, or any other legend). Preserve a clear image of the jacket legend and reel label so the printed designation, manufacturer/part number and marked voltage are legible. Record the manufacturer/part number and any marked voltage exactly as shown.
If you cannot fully read the jacket printing, mark the designation as unknown and include the best-visible characters. Do not combine multiple reels or runs under one generic label; treat unreadable printing as an explicit unknown and follow the split rules below.
Castle Rock’s development process covers new roads, water lines, subdivisions and commercial areas; engineered construction drawings typically include roads, water and sewer lines, stormwater, lighting and landscaping. That local context may explain a project record, but it does not make cable found at a site Type TC.
Castle Rock’s development process covers new roads, water lines, subdivisions and commercial areas; engineered construction drawings typically include roads, water and sewer lines, stormwater, lighting and landscaping. That local context may explain a project record, but it does not make cable found at a site Type TC.
- Required evidence fields: product designation, manufacturer/part number, marked voltage, jacket legend
- Take at least one close-up of the jacket text and one of each reel label or tag
- If printing repeats along the jacket, note the approximate spacing and any variations
Split similar assemblies—don’t lump them
Control and tray cable removed from prior service often contains multiple constructions that look similar in photos: different conductor counts, paired arrangements, gauges and shielding styles can be present on adjacent reels or cut lengths. Keep each distinct conductor count, pair count, gauge and shielding type on its own record line.
If two reels look alike but one has individual shields and the other only an overall shield (or none), list them separately. Where shielding is partially visible but not confirmed along the entire length, note shielding as “unknown” with the observed evidence and follow-up instructions.
- Separate evidence fields to record: conductor count, pair count, gauge, overall/individual shielding
- If shielding is only visible on the cut ends, record that under shielding evidence and indicate whether the observation is sample-based or continuous
- When in doubt, create a separate line for the unknown variant rather than merging quantities
Count continuous lengths and state the basis
List every continuous length individually. Distinguish measured footage from estimated footage and never sum cutoffs into a single continuous run. For each recorded run, supply a reel ID or reference, the measured continuous footage, and the quantity basis (measured, estimated, or counted pieces). Mark fitted ends (attached connectors or lugs) and any visible end condition.
If only a pile of cut pieces is available, inventory each piece if feasible and state that footage is per-piece measured; if measuring every piece is not feasible, provide representative samples and mark the remainder as estimated with the sample method described.
- Required evidence fields: reel ID, continuous footage, quantity basis, fitted ends
- Note explicitly when footage is estimated and describe the estimation method
- Do not combine measured and estimated lengths into a single footage number
Describe condition, history and release authority
State whether the material is stock, a project overrun, or removed from service. Note any visible jacket damage (abrasions, cuts, heat discoloration) and whether ends are fitted or open. Record the visible release authority (project manager, site release tag, decommission form) and the storage location where the reels or lengths are found.
If no release authority is visible, state that fact and include the site contact or document you attempted to locate. If history is unknown, mark it explicitly as “unknown” rather than assuming removed cable is unused stock.
- Required evidence fields: condition/history, jacket damage, release authority, storage location
- Photograph visible damage and the storage area to demonstrate context
- If release paperwork exists, cite it verbatim or attach a legible photo of the signature or tag
Common mistakes and the correct resolution
A frequent mistake is to label every cable removed from a tray as a single Type TC and report one combined footage total. That hides conductor count, shielding and continuous-length differences that affect sorting and review. The correct resolution is to use the actual printed legend and any matching records, keep unknown designations explicit, and separate every conductor/pair/shield configuration and continuous length into its own record.
If designations are illegible or missing, keep the item marked as unknown and provide all observed supporting details (gauge measured visually or noted from a sample, counted conductors, visible shielding). This preserves traceability and avoids incorrect aggregation of different constructions.
- Mistake: combining all tray-found cable under one Type TC footage total
- Resolution: transcribe marking, separate by conductor/pair/gauge/shielding, and list each continuous length separately
- If designation is unknown, mark it explicitly and include supporting measurements and photos
Illustrative worked example
Illustrative record (not a purchased lot): Reference CT-CR-04 shows a photographed TC-ER marking, construction listed as 12 conductors, 16 AWG with shielding unknown, and quantity recorded as 240 ft continuous, measured. Condition is described as removed cable with fitted ends present. This example demonstrates the required structure: exact marking transcription, separate construction description, measured continuous footage with the quantity basis, and visible condition notes.
When inventory is incomplete, follow the same template and mark fields you cannot confirm as unknown. State the steps needed to confirm unknowns—e.g., read another segment of the jacket, locate reel labels, or provide end-by-end photos.
- Example fields preserved exactly: reference CT-CR-04; marking TC-ER marking photographed; construction 12 conductors, 16 AWG; quantity 240 ft continuous, measured; condition removed cable, fitted ends present
- If additional verification is needed, request the specific photos or access required to read the jacket or reel label