Why exact designations matter
Control and tray cable come in many close-looking constructions where TC, TC-ER, PLTC or other printed designations determine safe use and classification. When reels or lengths are combined without checking markings and records, distinct constructions are easily merged and mischaracterized. That causes incorrect specification reporting and can prevent proper evaluation.
For sellers in Thornton, Colorado, the right approach is to transcribe the exact stamped or printed jacket designation for each continuous length and to keep separate lines for any differences in conductor count, pairs, shielding, jacket type or gauge. Storage location or where a cable was found is not a substitute for the printed designation.
The Thornton Water Treatment Plant began producing public water in late September 2020 and has a stated maximum capacity of 20 million gallons per day.
This is utility context, not evidence that a particular control or tray cable came from the plant; offered cable still needs its own markings and records.
- Record the exact jacket designation (TC, TC-ER, PLTC, or other) from the jacket print.
- Do not infer type from the tray or storage location.
- Keep a distinct line for each continuous length that has different markings or construction.
Step-by-step seller task
Follow the supplied steps when preparing control/tray cable lots. Step 1: Transcribe the designation — copy the exact printed marking and record manufacturer, part number and marked voltage in the same line. Step 2: Keep variations separate — list conductor count, pair count, gauge, shielding and jacket separately on dedicated lines rather than lumping multiple constructions together. Step 3: Preserve quantity evidence — measure or document continuous footage for each reel or cut length, note fitted ends and state the quantity basis (measured, documented, or estimated). Step 4: Match records and photos — tie photos, jacket printing and any data-sheet reference to the same line ID; if fields are unreadable, leave them as unknown rather than guessing.
These steps are the basis for our evaluation. Provide clear photo filenames mapped to each line ID and keep unknown fields explicitly flagged so we know which items need further verification.
- Transcribe designation: include jacket designation, manufacturer, part number, marked voltage.
- Separate lines: list conductor count, pair count, gauge, shielding, jacket.
- Quantity: include line ID, continuous length, quantity basis, fitted ends.
- Match records: attach photo filenames and data-sheet references; list unknown fields.
How to describe removed cable and fitted ends
Removed cable with fitted ends should be documented per-line. For each continuous length, record whether ends are fitted and the measured continuous footage. If the jacket printing is partially unreadable, mark the jacket designation as unknown and provide clear photos of the unreadable area plus neighboring readable segments. Do not relabel unknowns as TC simply because the cable was removed from a tray.
If you cannot read the entire jacket marking, capture high-resolution photos at multiple points along the length and include close-ups of any label, tag or spool stamp. Note the condition field (for example, removed cable; fitted ends present) and supply a quantity basis: measured, documented, or estimated.
- Note fitted ends on the same line as continuous length and measurement.
- If designation is unreadable, mark as unknown and supply photos and any available data-sheet references.
- Record quantity basis: measured, documented, or estimated.
What differences require separate lines
Separate lines are required whenever conductor count, pair count, gauge, shielding (overall or individual), or jacket construction differs between continuous lengths. Even a single conductor count difference or presence/absence of shield means the line is a distinct specification. Use individual fields for conductor count, pair count, gauge, shielding and jacket so reviewers can compare items without revising your records.
If a reel shows mixed, unreadable or intermittent printing, isolate each continuous segment that can be positively identified and list the remainder as unknown with photos and measured footage.
- Different conductor count = separate line.
- Different pair count or gauge = separate line.
- Different shielding (overall/individual) or jacket = separate line.
How to handle unknown or incomplete inventory
When fields are unknown, preserve that status rather than guessing. Use the 'unknown fields' evidence field and include supporting photos and a clear description of what is unreadable. Provide an estimated continuous length and mark the quantity basis as estimated if you cannot measure. Note any data-sheet references even if they are generic; tag them to the same line ID so they can be checked.
Be explicit about what you could not confirm: if shielding is not visible without cutting the jacket, mark shielding as unknown and document why. Our process accepts unknowns for initial review but requires that unknown items stay flagged so the lot can be prioritized for clarification or in-person inspection.
- Flag unreadable fields as unknown and attach photo evidence.
- Supply estimated continuous footage only when measurement is not possible and mark the quantity basis accordingly.
- Do not relabel unknown designation as TC based solely on location or removal from a tray.
Illustrative record (example)
Provide a sample line entry like the illustrative example below to show how fields should be supplied. This example is explicitly not a purchased lot; it demonstrates the required format so reviewers understand how to map photos and data sheets to each line.
Use a unique line ID for each continuous length and include description, measured or estimated quantity, condition and shielding status. If any field is unknown, list it in the 'unknown fields' evidence with supporting photo filenames.
- Illustrative example — not a purchased lot: Line ID CT-T-04; Description: TC-ER marking; 12 conductors, 16 AWG; Quantity: 240 ft measured continuous; Condition: removed cable; fitted ends present; Shield: unknown