What we need first: exact jacket marking
The single most important data point is the actual printed designation on the jacket. Record TC, TC-ER, PLTC or any exact printed text plus manufacturer, part number and voltage when readable. If the marking is unreadable, mark designation certainty as unknown and attach close-up photos of the jacket text and end labels.
Do not assume every cable taken from a tray is the same Type TC product. The jacket text and part number are the primary evidence we use to separate items that look similar but differ in rating or intended use.
- Evidence fields required: printed designation, manufacturer, part number, voltage marking, jacket text
- Action: transcribe the full continuous jacket printing and attach a readable photo of the printing
Separate by conductor, pair and shielding
Keep separate lines for any materially different conductor counts, pair counts, gauges or shielding. For multi-conductor cable the difference between 4, 7, 12 or 24 conductors — and whether an overall braid, foil shield or no shield is present — changes classification and review.
Do not merge reels simply because they came from the same tray or project area. If conductor count or shielding is unknown, record that fact and create a distinct line with designation certainty set to 'unknown' rather than folding it into another line.
- Evidence fields required: conductor count, pair count, gauge, shielding, jacket, designation certainty
- Action: list each construction variant on its own line with photos showing conductor cross-section or cut end when possible
Quantities, length and fitted ends
Provide continuous footage and the basis for that number for each reel or cut length: measured, documented or estimated. Indicate reel or line ID and whether ends are fitted with lugs, connectors or are cut. Note if cable was removed from equipment (removed) versus left uninstalled.
If fitted ends are present, photograph them and note if they are factory-terminated or field-fitted. That detail affects how a line is described and must remain a separate evidence field.
- Evidence fields required: reel/line ID, continuous length, measured/documented/estimated, fitted ends, condition/history
- Action: annotate a drawing or label for each reel so reviewers can trace quantity back to a physical reel or cut
Photos, storage and release facts
Attach overview photos of the reel or cut, close-ups of the jacket printing, label and any identification tags. Include photo references in the line record and attach any available data sheet that matches the printed part number.
State where the material is stored, what records are available, and who can authorize release. If the release authority is unknown, say so explicitly. Access notes (hours, gate procedures or contact requirements) should be included to avoid delays during inspection or pickup.
JAXPORT says its three marine terminals handle every type of general and project cargo; its facilities page identifies containerized, breakbulk, heavy-lift and liquid-bulk activity among terminal operations. This is limited local cargo context, not evidence that a terminal has control cable; the seller still needs close-up marking photos, the actual storage location, and release authority.
- Evidence fields required: photo references, data sheet, storage location, release authority, access notes
- Action: supply a compact photo checklist: overview, jacket printing, cut end, fitted end, label
How to handle unknown or mixed information
If markings are missing or smudged, do not guess. Retain an 'unknown designation' line and keep the construction facts you can confirm (gauge, conductor count, visible shield). Where length is estimated, mark the measurement basis clearly so reviewers know the confidence level.
When multiple reels look similar but differ on any required evidence field, list each reel separately. The common mistake we see is combining removed tray cable into one Type TC classification; the correct resolution is explicit: use actual markings and matching records and keep materially different constructions on separate lines.
- Action: record designation certainty for each line and never merge unknown-designation material with a known-designation line
- Action: if the data sheet is not available, include all photographed jacket text and a measured cross-section photo if safe and practical
Illustrative record (how to present one line)
Provide a concise line record for each distinct construction. Below is an illustrative example format showing the exact fields we expect for one line. This is a sample only and not a purchased Jacksonville lot.
Use the same field names and values to minimize back-and-forth during review.
- Reference: CT-JAX-05
- Description: TC-ER marking; 12 conductors, 16 AWG; shielding unknown
- Quantity: 240 ft continuous, measured
- Condition: removed cable with fitted ends present
- Records: matching data sheet unknown