Transcribe the designation before grouping reels
Photograph and copy the complete readable jacket marking, including TC, TC-ER, PLTC, or another designation only when it actually appears. Add manufacturer, part number, and marked voltage to the same reel reference. Cable found in a tray is not automatically Type TC, and an adjacent machine or tray location is not a substitute for a product marking.
Where printing is incomplete, record the legible text and label the missing portion unknown. Keep the affected reel on its own line until the product can be matched. This avoids turning a storage location into a technical identification.
- Actual jacket designation.
- Manufacturer, part number, and marked voltage.
- Reel ID and photo reference.
- Partial or unknown marking stated explicitly.
Split the variants that change the inventory line
Use separate lines for different conductor or pair counts, gauges, shielding arrangements, jacket markings, and continuous lengths. Two black multi-conductor reels can be different products even when their outside appearance is similar. Record fitted ends and visible jacket condition with the appropriate reel rather than attaching one condition note to an entire group.
Record whether a reel is uninstalled stock, project overrun, or previously removed cable, along with any known history. A removed piece with fitted ends should not be blended with an uninstalled reel merely because their visible markings overlap.
- Conductor or pair count and gauge.
- Shielding and jacket detail.
- Continuous footage with measured, documented, or estimated basis.
- Status, known history, fitted ends, and visible condition.
Keep local context limited to access facts
A City planning document identifies industrial land uses as manufacturing, warehousing, distribution, freight logistics and other industrial operations, and says such zones require strong transportation access. The fact does not establish a control-cable lot; it simply supports documenting the actual storage and access circumstances for the reels the seller offers.
Add a site reference, release contact, and known loading constraints after the specification lines are clear. These are seller-supplied records for the particular inventory, not a promise that any movement or handling arrangement has been made.
- Storage site reference.
- Release authority or pending status.
- Known access restrictions.
- Dimensions or weight basis when available.
Worked record and unreadable cable
Illustrative example—not a purchased lot: CT-SF-01 is marked TC-ER with 12 conductors at 16 AWG; shielding is unknown. It has 240 ft measured, fitted ends, and a removed-cable status. The line does not silently convert the unknown shield into a specification.
If footage is uncertain, state the best supported basis and retain the reel as a separate record. If the designation is unreadable, provide the photo, visible conductor or pair count when safely known, and the unknown field. Do not collapse multiple uncertain reels into one footage total.
- Example fields: designation, count, gauge, shielding, footage, basis, status, fitted ends.
- Keep an unreadable designation separate from a confirmed product.