Start with the copper construction
Make a line for each actual construction before adding a quantity. Bare conductor, insulated single-conductor wire, and multi-conductor cable should not share a description simply because each contains copper. Copy the manufacturer, part number, size, and printed insulation or jacket designation wherever they remain legible.
Keep material intended only for recovery on its own line rather than folding it into an identified reel balance. That separation preserves the product record for an identifiable reel and makes the condition of short or mixed pieces clear without assigning a product designation they do not have.
- Use a unique reel reference before taking photos.
- Record conductor metal and the readable product designation.
- Mark each line as bare, insulated, multi-conductor, or recovery-only.
Establish the current footage
The footage printed on a new-reel label may describe the amount originally supplied, not the amount left. For every reel or continuous cut, record a current balance and call it measured, documented, or estimated. Keep separate rows when two partial reels have the same product number but different remaining lengths.
If the balance is estimated, state the method in the record: a reel counter, an internal count sheet, or a visual estimate. Do not turn several cuts into one continuous length. The useful question is what each physical piece can document now, not the sum that appeared on a purchase record.
- Record reel reference and full, partial, or cut status.
- State the continuous footage and its quantity basis.
- Attach a photo of any tag used to support the balance.
Keep loaded-reel weight in its own field
A scale figure for a loaded reel is a handling fact, not a verified conductor quantity. Record it as gross loaded-reel weight, identify the ticket or scale source, and keep cable-only or conductor weight unknown unless an existing record supports that different value. Wood, steel, insulation, and packaging do not disappear because a total is rounded.
A common listing error is to call a 900 lb loaded wooden reel “900 lb of copper” while several gauges are combined in one row. Correct the record by retaining the 900 lb gross figure, separating the marked constructions, and leaving conductor weight unknown. That is more useful than an unsupported conversion.
- Label gross loaded-reel weight separately from cable-only weight.
- Name the source for a documented weight.
- Do not convert a gross figure into copper content.
Match photos to ownership and location
Use the same reference in the inventory, photo filenames, and any weigh-ticket file. A clear set normally includes a full reel view, tag, readable jacket legend, accessible ends, and any visible damage. Then note the storage or project location and the person or role that can authorize release; an unknown authority should remain pending in the record.
Ann Arbor’s updated FY2026–2031 Capital Improvements Plan includes 461 projects and $1.167565 billion in funding needed during FY2026–2031; Water (101 projects), Streets and Bridges (88), and Stormwater (88) are the top three asset groups by project count. For a contractor organizing project leftovers, that city context is a reason to retain a project reference with the reel record; it does not identify a particular copper lot or imply that the City is involved in this inquiry.
- Match tag, jacket, overview, and weight photos to the reel reference.
- State the storage or project location without publishing an address.
- Record ownership and release authority, or mark them pending.
Use a factual worked copper record
Illustrative inventory example—not a purchased lot: CU-AA-01 is an identified insulated copper cable entry with manufacturer and part number documented. The quantity field reads “two partial reels; 640 ft measured and 210 ft estimated,” while the weight field reads “900 lb gross loaded-reel; conductor weight unknown.” The status field says “uninstalled; release authority pending.”
This example does not assume the two reels are interchangeable or that gross weight establishes metal content. If the second reel has a different gauge, tag, or condition, it becomes a separate record. If a required field cannot be verified, say unknown and preserve the photograph or document that explains the gap.
- Keep one worked line for each distinct construction or condition.
- Preserve measured and estimated footage as different facts.
- Use unknown rather than guessing conductor weight or release status.