Why exact designation matters
Control and tray cable families include TC, TC-ER, PLTC and many manufacturer-specific jacket markings. Two cables that look alike on a reel can be different products: conductor count, gauge, shielding and voltage rating determine proper classification.
When lots are described only by where the cable was stored (for example, “removed from tray”) it's common to combine reels with different pair counts or shielding. That obscures true composition and forces follow-up questions, delays and possible rejection.
Richardson Economic Development identifies communications-equipment, semiconductor, aerospace, healthcare and technology manufacturers among the city’s major employers, including CommScope, Qorvo and Texas Instruments. This is local commercial context only: it supports keeping communications and manufacturing cable variants distinct, not an assertion that any named employer has cable available.
- Provide a photographed printed designation from the jacket; do not infer type from location.
- Separate each distinct conductor/pair count, gauge and shield arrangement into its own inventory line.
Step 1 — Transcribe the designation
Take clear photos of the cable jacket showing any printed designation (for example, TC, TC-ER, PLTC or manufacturer part numbers). Copy that text into your inventory entry exactly, and note marked voltage if present.
Required evidence fields for this step include printed designation, manufacturer, part number and marked voltage. If markings are partially unreadable, record that under uncertainties and supply the photo filename pointing to the image of the unreadable area.
- Photo the jacket along a continuous length if possible so serial printing and part numbers are visible.
- Use an inventory reference that appears on your reel tag and in the photo filename to avoid mismatches.
Step 2 — Split construction variants
Create separate inventory rows for every meaningful construction difference: conductor count, pair count, gauge, shielding (foil, braid, combination or none) and jacket type. Retain the per-reel length rather than adding different reels into a single total unless they are truly identical.
Required evidence: conductor count, pair count, gauge, shielding, jacket and per-reel length. If a reel's shielding is unknown, mark shielding as unknown and attach photos showing the jacket and cross-section if available.
- Do not combine 8-conductor 18 AWG reels with 12-conductor 16 AWG reels even if both came from the same tray.
- If a reel contains paired conductors bundled differently than others, record pair count and describe the bundle in the construction field.
Step 3 — Record condition and ends
For each inventory line, state whether the cable is uninstalled on full reels, partial/continuous footage, removed (cut) or has fitted ends. Note jacket damage, fitted connectors, or unreadable markings. Continuous footage should be measured and recorded per reel.
Evidence fields for this step include condition, continuous footage, fitted ends, jacket damage and unknown fields. If ends are fitted, list the type present (for example, factory lug, field-terminated) as a descriptive note — do not provide handling instructions.
- Measure continuous footage where possible; label partial reels with the measured footage and a clear reel reference.
- If markings cannot be read because an end is fitted or jacket damage obscures print, capture a photo of the fitted end and note which side is unreadable.
Step 4 — Match documents and photos
Use stable references so photos, reel tags and data sheets can be cross-checked. Attach matching manufacturer data sheets when available and include the photo filenames and inventory reference in the record. Explicitly mark mixed reels or unreadable lines as unknown instead of guessing construction.
Evidence fields required here are inventory reference, photo filenames, matching data sheet and uncertainties. Keeping everything cross-referenced reduces back-and-forth and enables a faster review.
- Include the inventory reference on each reel tag and use that same reference as a photo filename prefix.
- If you cannot find a manufacturer data sheet, note the attempted search and leave the matching data sheet field blank rather than guessing specification values.
Handling unknown or incomplete inventory honestly
If markings are unreadable, or you do not have per-reel length or manufacturer records, mark those fields explicitly as unknown in your submission. Provide the photos that show the unreadable area and the reel tag so we can assess what can be verified remotely.
Do not collapse different conductor or pair counts into a single line to mask unknowns. Instead, create separate lines flagged with unknown fields and include an explanation in the uncertainties field describing what information is missing and why.
- When in doubt, record the uncertainty: list the field as unknown and attach supporting photos.
- A transparent record that shows what is unknown speeds decisions; hiding mixed items under a single designation causes the exact mistake we aim to avoid.
Illustrative record (example)
Use a clear example to model your submission. The following is a fictional illustrative record — not a purchased Richardson lot — showing the required fields and format.
Follow the example pattern: inventory reference, exact designation from the jacket photo, clear construction description, measured continuous footage, and a condition statement including fitted ends and any damage or unreadable areas.
- Example record label: Illustrative record — not a purchased Richardson lot
- Included fields: reference CT-R02; designation TC-ER marking photographed; construction 12 conductors, 16 AWG; shielding unknown; quantity 240 ft continuous, measured; condition removed cable; fitted ends present.