What we need first: marked rating and ID
Begin with a photograph and transcription of the reel's actual marking: the kV rating printed on the jacket, the manufacturer's name and the full part number. Also capture any reel ID stamped on the drum or attached tag. Each reel is reviewed independently; do not substitute markings from neighboring reels or from a general project label.
Why this matters: the marked kV and part number are primary evidence fields that allow us to match any batch or test records you provide. Missing or ambiguous markings require explicit notation rather than inferred values.
The City of Richardson says its economic-development department works on business attraction, retention and expansion, real-estate redevelopment, workforce development and innovation ecosystem building. That city role is limited local context for a facility or redevelopment release record; it is not evidence that medium-voltage cable is available or that a transaction will occur.
- Photograph the kV marking and the entire part number on the jacket
- Transcribe the manufacturer name exactly as marked
- Record the reel ID visible on the drum or tag
Match construction records to the reel or batch
Attach any existing construction or test records only when they explicitly reference the photographed reel ID, part number or the stated batch/lot ID. Records that reference a different batch or an indistinct project should be listed but not applied to the photographed reel as a match.
Accepted construction records include insulation level, conductor metal and size, and shield or neutral construction — but only when the record and the reel match. If a record is missing or references a different batch, leave the field explicitly unknown.
- Include insulation level, conductor metal/size, shield/neutral and batch/lot ID
- Attach PDF or image of records that cite the reel ID or batch number
- If no matching record exists, state that the item has no matching test record
Document condition history and end details
Provide continuous footage documented from the reel, describe end protection (caps, taped ends, exposed conductor) and note any signs of moisture exposure or storage impacts. State whether the reel is uninstalled, partial (with footage removed), or removed from service.
Condition history should include storage history and any known handling events. If a reel is missing an end cap or shows exposure, state that explicitly rather than inferring later repairs or protections.
- Record continuous footage and end condition
- Note moisture exposure and storage history (indoor/outdoor, covered/uncovered)
- State condition status: uninstalled, partial, or removed
Handling, dimensions and access details (kept separate)
List approximate reel dimensions, a documented weight basis (gross, net, or unknown), the storage location ZIP and any access limits. These handling details are for planning inspections and quotes; they do not imply removal, transport, or acceptance.
Clearly separate handling notes from product specifications: weight and dimensions help evaluate lifting and transport but are not a substitute for the required electrical and construction evidence.
- Provide dimensions and documented weight basis (gross/net/unknown)
- Give exact storage location ZIP and any access restrictions
- Do not imply agreed removal, trucking or acceptance
How we treat missing or mismatched documentation
If insulation level, shield/neutral, batch ID or test history is missing, leave those fields explicit and marked unknown. Do not attach a certificate or test report from a different batch or a visually similar reel as a substitute. The common mistake is using a matching-looking reel or a certificate from another batch to fill gaps; this practice invalidates traceability.
Our resolution: all matched records must reference the photographed reel or that reel's batch/lot. Documentation is a statement for review, not a reuse certification or a purchase guarantee.
- Mark any missing specs as unknown rather than substituting non-matching records
- Match each attached record to the reel's part number, reel ID or batch/lot ID
- Understand documentation is for review only, not a guarantee of purchase
Illustrative record (example — not a purchased lot)
Use a clear, honest example to format your submission. An illustrative entry might read: reference MV-R03; 15 kV marking photographed but insulation level unknown; 720 ft documented; uninstalled reel with one missing end cap; no matching test record and batch reference unknown.
Providing this level of specificity speeds review and reduces follow-up. When records are incomplete, call out what is missing so reviewers can request targeted confirmations rather than re-review the whole reel.
- Example fields: reference, rating text, footage, condition summary, records status
- Label illustrative or sample entries explicitly as not a purchased lot