What we need first: transcribe the designation
Start by photographing and transcribing the full jacket legend and any attached reel tags exactly as printed. Preserve TC, TC-ER, PLTC or other printed designations without abbreviation or interpretation. If a manufacturer name or part number is present on the jacket or tag, record it verbatim.
Why: the printed designation and part number are the primary evidence that ties a physical piece to a manufacturer construction and data sheet. Without that exact string it is easy to conflate different constructions that look similar.
Milwaukee’s Industrial Land Analysis reports about 45,000 industrial jobs, over $3.6 billion in wages and about 2,160 businesses in seven Industrial BIDs. That citywide context can make an exact control-cable inventory useful, but it does not establish a particular Milwaukee reel, owner, or purchasing need.
- Evidence to capture: manufacturer, part number, designation, marked voltage
- Capture high-resolution photos of both sides of the reel tag and 12–24 inch jacket span showing the legend
- If the marking is partially worn, mark those characters as illegible and record that as an unknown field
Split construction differences into separate fields
Do not combine conductor count, pair count, gauge or shielding into a single line. Record each attribute as its own field so multiple reels from the same area can be separated into distinct sale lots.
For example, list conductor count separately from pair count and note shields as overall braid, foil-over-drain, individually shielded pairs, or no shield. Record jacket type (PVC, LSZH, etc.) as printed on the legend when present.
- Evidence to capture: conductor count, pair count, size, shielding, jacket
- If pair count and conductor count differ (for example, 12 conductors formed as 6 pairs), record both values
- If shielding is not visible, mark shielding as unknown rather than assuming
Document each physical piece and status
For each reel or cut length, record continuous footage, fitted ends, physical condition and whether the cable was uninstalled or removed from service. Use measured continuous length for reels where feasible and label any calculated or estimated length as an estimate.
State fitted ends explicitly: presence of connectors, insulation cutbacks, or taped ends affects how a buyer will treat the piece, and it is an evidence field in our required list.
- Evidence to capture: reel ID, continuous length, quantity basis, fitted ends, service history
- If a piece was previously in service, record its prior location as context but not as proof of type
- When length is estimated, prefix the value with the word ESTIMATE
Attach and match supporting records
Only attach a data sheet, cut sheet or inspection record to the specific reel or line it actually describes. Do not attach a manufacturer spec sheet to multiple reels unless the reel’s part number or jacket marking exactly matches the sheet.
If you cannot find a matching record for a reel, mark the document reference field empty and record which fields remain unknown so a buyer can assess risk.
- Evidence to capture: document reference, matching reel/batch ID, unknown fields
- If a manufacturer catalog page is used, note the page or file name and the exact string that matches the jacket legend
- When a record is missing, explicitly list which required evidence fields are unknown
How to present mixed or uncertain inventories
When project closeouts combine visually similar reels, split them into separate line items unless every required evidence field matches exactly. For items with partial data, present a line item with the fields you have and mark unknown fields—do not infer missing attributes from nearby reels.
If multiple reels share the same part number and jacket legend, they may be grouped; if any attribute (conductor count, shield type, gauge) differs they must remain separate lots.
- If a reel’s shielding is erased or damaged and cannot be confirmed, set shielding to unknown in the record
- Do not use a storage or prior-service location as sole evidence that an item is Type TC; use markings and manufacturer records instead
- Label all estimated lengths and report any fitted ends or removed-service indicators
Illustrative record (use this as a template)
Use a record template like the illustrative example below to prepare each line item. This example is illustrative only and not a purchased lot.
Provide a single-line example that exactly records each required field so buyers can quickly evaluate what is verified and what is unknown.
- Example line (illustrative): Line CT-MKE-03 — designation: TC-ER marking photographed; 12 conductors, 16 AWG — quantity: 240 ft measured continuous — condition: removed cable; fitted ends present; shielding unknown