What we need first: capture the actual rating
Start by photographing and transcribing any marking on the reel flange or jacket that indicates kV, the manufacturer name, and the complete part number. The photographic record should clearly show reel identification (reel ID) next to the marking. If the reel bears multiple markings, photograph each and describe how they relate.
Record reel ID, marked kV, manufacturer and part number as separate fields. If one is missing, state that explicitly; do not substitute markings from another reel or a certificate. A photographed marking tied to the physical reel is the starting point for a traceable rating record, not a promise about the cable.
Milwaukee DPW Infrastructure maintains streets, bridges, signals, street lighting, storm water, sewers, city-owned buildings and parks; Transportation Operations oversees underground conduit. That public scope makes a precise handoff record relevant for distribution-related inventory, but it does not identify a DPW cable lot or establish ownership, specification, or buyer interest.
- Required evidence: reel ID, marked kV, manufacturer, part number
- If multiple kV markings conflict, note each and attach photos; do not guess final rating
Keep construction fields explicit and supported
Record insulation level, conductor size and metal, shield or neutral details, and visible end protection only when the reel itself or a matching record supports those fields. Do not infer insulation class or shield construction from a generic voltage marking alone.
Supply the construction evidence fields: insulation, conductor size/metal, shield/neutral, and end protection. If the reel lacks end caps or protection, report that condition and whether the cable ends are sealed, exposed, or wrapped. When a supporting manufacturer drawing or production sheet is available and explicitly references the reel ID or batch/lot ID, attach it and indicate the matching fields.
- Attach manufacturer part-number documentation when it directly references the part number on the reel
- When insulation level is unknown on the reel itself, mark the field unknown rather than using a same-model assumption
Link records to the reel — don’t mix batch sources
Match production, batch or test records by reel ID and record date. Use the evidence fields batch/lot ID, record date, record scope, and document match status to show whether a document directly applies to the offered reel. If a certificate references a different lot or a manufacturer run but not the reel ID, mark it as not matched and do not treat it as traceable proof.
When records are absent, disclose which documents are missing and whether you searched warehouse receipts, manufacturer test reports, or facility history records. If a document applies only to another batch, identify the mismatch clearly: name the other batch ID and state that it does not match the offered reel.
- Do not attach certificates from different reels to fill missing history
- If only partial records exist (for example, date but not lot ID), report the partial fields and mark document match status accordingly
Report condition and quantity per continuous length
List each continuous length of cable wound on the reel and report storage history, moisture exposure, visible damage, and the basis used to estimate reel weight. Use the continuous footage, storage history, visible damage, weight basis, and reel dimensions fields to be explicit.
If the reel is uninstalled, note that and provide footage documented on the reel tag or measured by a validated inventory record. If footage is estimated (for example, by flange diameter), state the estimation method and do not present it as a precise certifiable measurement.
- Include whether the reel has been re-spooled or had end caps replaced
- When photos are provided, label them with date and what they show; do not present photos as electrical certification
How to handle unknown or incomplete inventory honestly
If a field cannot be supported by the reel, the reel tag, or a record that explicitly references the reel ID, leave that field unknown. The correct action when records are missing is to identify the mismatch and disclose which supporting documents are absent rather than substituting from other batches.
Follow the brief resolution: leave unsupported fields unknown, identify any mismatch, and attach only records traceable to the offered reel. Do not test, cut, or alter the cable for the inquiry; indicate when an end protection is missing or when testing would be required by a buyer to confirm a property.
- When a similar-looking reel exists in the same stock, document its differences and avoid using its certificate
- State clearly when footage or insulation level is 'unknown' and why
Illustrative record and seller confirmation steps
Provide a concise illustrative record using the example label and fields so reviewers see the expected format. For example: line MV-MKE-11, 15 kV marking photographed; insulation level unknown, 720 ft documented on one uninstalled reel, one missing end cap; no matching batch test record located. Mark the record as illustrative and not a purchased lot.
Before submitting, check the required evidence list and attach only records that match the reel. Keep price, acceptance, inspection and transport questions for a lot-specific discussion after the inventory has been reviewed; this documentation does not settle those terms.
- Example label: Illustrative only — not a purchased Milwaukee lot
- Required evidence checklist accompanies submissions for reviewer use